- Home
- >
- News
- >
- Accommodation needs
- >
Accommodation needs
2024-05-22 17:21
The weight of the structure is only 1/5 of the weight of traditional brick-concrete structures. This greatly reduces the load during earthquakes and is highly safe. In addition, imported high-strength screws and bolts are used to connect and fix the skeleton and frame, making the installation scientific and fast. At the same time, structural calculations are performed for each building during design, and the foundation and overall building structure are designed based on structural calculations. Structural calculation is the result of experiments and practices in the United States and Japan, and has patented technology rights and national recognition certificates.
Steel is a non-combustible material and is protected by deep galvanizing, which is anti-corrosion and termite-proof, and can automatically repair damage to the coating.
Light steel structure residences use external heat insulation method: This method takes advantage of the unique properties of thin-walled light steel structures. The thermal insulation performance of thin-walled light steel structures utilizes the principle of external heat insulation. There is an air layer inside the wall. The characteristic of roof connection ensures that the heat is a poor conductor and its principle is similar to that of a thermos bottle. The skeleton is tightly covered with thin plastic heat-insulating and moisture-proof materials from the outside, and then is added with heat-insulating materials. There is an air layer outside the heat-insulating materials. Various materials can be used outside the air layer according to the customer's requirements for the building exterior wall. Perform various exterior wall treatments. The external heat insulation method does not require heat insulation treatment inside the frame, and the interior wall can be directly treated.
Thus, on the basis of not increasing the construction cost, excellent energy-saving and thermal insulation effects are achieved through the treatment of the building structure, and the disadvantages such as moisture and insects caused by condensation are overcome. Therefore, this thermal insulation method has been rapidly adopted. Replaces internal insulation methods. This ensures that the thin-walled light steel structure is warm in winter and cool in summer. When the outdoor temperature is 0 degrees, the indoor temperature can still be maintained at 17.2 degrees with natural air convection to regulate the indoor temperature to ensure warmth in winter and coolness in summer.